Item type |
Multiple(1) |
公開日 |
2025-03-30 |
タイトル |
|
|
タイトル |
Preflight calibration and performance of the Astro-E2/HXD-II anti counter as the all sky monitor |
|
言語 |
en |
作成者 |
Ohno
Fukazawa
Yamaoka
Kokubun
Terada
古徳
Hong
Mori
Makishima
Murakami
Nakazawa
Takahashi
Tashiro
|
アクセス権 |
|
|
アクセス権 |
metadata only access |
|
アクセス権URI |
http://purl.org/coar/access_right/c_16ec |
主題 |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
BGO |
主題 |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
Calibration |
主題 |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
Gamma-ray burst |
主題 |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
Soft gamma-ray detector |
主題 |
|
|
言語 |
en |
|
主題Scheme |
SciVal |
|
主題 |
Radiation |
主題 |
|
|
言語 |
ja |
|
主題Scheme |
SciVal |
|
主題 |
放射線 |
主題 |
|
|
言語 |
en |
|
主題Scheme |
SciVal |
|
主題 |
Nuclear and High Energy Physics |
主題 |
|
|
言語 |
ja |
|
主題Scheme |
SciVal |
|
主題 |
核物理学および高エネルギー物理学 |
主題 |
|
|
言語 |
en |
|
主題Scheme |
SciVal |
|
主題 |
Radiology Nuclear Medicine and imaging |
主題 |
|
|
言語 |
ja |
|
主題Scheme |
SciVal |
|
主題 |
放射線学、核医学およびイメージング |
内容記述 |
|
|
内容記述タイプ |
Abstract |
|
内容記述 |
<p>The Hard X-ray Detector (HXD-II) onboard Astro-E2 consists of the main detector which has its energy range from 10 to 600 keV and the active shield detector for background reduction. This shield detector (Anti detector) is designed to not only for the background reduction but also for the soft gamma-ray all sky monitor of Gamma-ray bursts (GRB) and black hole binaries. The asymetric shape and large size of BGO scintillators for the Anti counter make the gamma-ray response very complicated, and thus we need the careful calibration before the launch. We then performed preflight calibrations of HXD-II in 2003-2004. For the Anti detector, we measured the pulse height spectra and stopping power of the unit detector before integration by exposing it to the collimated gamma-ray. After integration of HXD-II, we measured the pulse height spectra and stopping power of the Anti detector by irradiating the gamma-ray source from various direction. Furthermore, we performed the same measurement after placing the HXD-II detector on the Astro-E2 spacecraft. Taking into account these experimental results, we construct the gamma-ray response by the Geant4 Monte Carlo simulation. The response developed in this work was found to reproduce the experimental spectra and the count distributions of each unit counter with 10-20 % accuracy.</p> |
|
言語 |
en |
日付 |
|
|
日付 |
2004 |
|
日付タイプ |
Issued |
Language |
|
|
言語 |
en |
資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_f744 |
|
資源タイプ |
conference proceedings |
バージョン情報 |
|
|
バージョン情報 |
N16-20 |
収録物識別子 |
|
|
収録物識別子タイプ |
ISSN |
|
収録物識別子 |
1095-7863 |
収録物名 |
|
|
収録物名 |
IEEE Nuclear Science Symposium Conference Record |
巻 |
|
|
巻 |
1 |
ページ数 |
|
|
ページ数 |
5 |
開始ページ |
|
|
開始ページ |
405 |
開始ページ |
|
|
開始ページ |
409 |