ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 10 学術雑誌論文
  2. Pure

Preflight calibration and performance of the Astro-E2/HXD-II anti counter as the all sky monitor

https://teikyo-u.repo.nii.ac.jp/records/2024847
https://teikyo-u.repo.nii.ac.jp/records/2024847
42474330-7a88-438b-b404-e3ba10227f1f
Item type Multiple(1)
公開日 2025-03-30
タイトル
タイトル Preflight calibration and performance of the Astro-E2/HXD-II anti counter as the all sky monitor
言語 en
作成者 Ohno

× Ohno

Ohno
M.

Search repository
Fukazawa

× Fukazawa

Fukazawa
Y.

Search repository
Yamaoka

× Yamaoka

Yamaoka
K.

Search repository
Kokubun

× Kokubun

Kokubun
M.

Search repository
Terada

× Terada

Terada
Y.

Search repository
古徳

× 古徳

en kotoku jiyunichi

ja 古徳 純一

Search repository
Hong

× Hong

Hong
S.

Search repository
Mori

× Mori

Mori
M.

Search repository
Makishima

× Makishima

Makishima
K.

Search repository
Murakami

× Murakami

Murakami
T.

Search repository
Nakazawa

× Nakazawa

Nakazawa
K.

Search repository
Takahashi

× Takahashi

Takahashi
T.

Search repository
Tashiro

× Tashiro

Tashiro
M.

Search repository
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_16ec
主題
言語 en
主題Scheme Other
主題 BGO
主題
言語 en
主題Scheme Other
主題 Calibration
主題
言語 en
主題Scheme Other
主題 Gamma-ray burst
主題
言語 en
主題Scheme Other
主題 Soft gamma-ray detector
主題
言語 en
主題Scheme SciVal
主題 Radiation
主題
言語 ja
主題Scheme SciVal
主題 放射線
主題
言語 en
主題Scheme SciVal
主題 Nuclear and High Energy Physics
主題
言語 ja
主題Scheme SciVal
主題 核物理学および高エネルギー物理学
主題
言語 en
主題Scheme SciVal
主題 Radiology Nuclear Medicine and imaging
主題
言語 ja
主題Scheme SciVal
主題 放射線学、核医学およびイメージング
内容記述
内容記述タイプ Abstract
内容記述 <p>The Hard X-ray Detector (HXD-II) onboard Astro-E2 consists of the main detector which has its energy range from 10 to 600 keV and the active shield detector for background reduction. This shield detector (Anti detector) is designed to not only for the background reduction but also for the soft gamma-ray all sky monitor of Gamma-ray bursts (GRB) and black hole binaries. The asymetric shape and large size of BGO scintillators for the Anti counter make the gamma-ray response very complicated, and thus we need the careful calibration before the launch. We then performed preflight calibrations of HXD-II in 2003-2004. For the Anti detector, we measured the pulse height spectra and stopping power of the unit detector before integration by exposing it to the collimated gamma-ray. After integration of HXD-II, we measured the pulse height spectra and stopping power of the Anti detector by irradiating the gamma-ray source from various direction. Furthermore, we performed the same measurement after placing the HXD-II detector on the Astro-E2 spacecraft. Taking into account these experimental results, we construct the gamma-ray response by the Geant4 Monte Carlo simulation. The response developed in this work was found to reproduce the experimental spectra and the count distributions of each unit counter with 10-20 % accuracy.</p>
言語 en
日付
日付 2004
日付タイプ Issued
Language
言語 en
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_f744
資源タイプ conference proceedings
バージョン情報
バージョン情報 N16-20
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 1095-7863
収録物名
収録物名 IEEE Nuclear Science Symposium Conference Record
巻
巻 1
ページ数
ページ数 5
開始ページ
開始ページ 405
開始ページ
開始ページ 409
戻る
0
views
See details
Views

Versions

Ver.1 2025-04-14 23:28:03.101139
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3