{"created":"2025-05-21T13:21:35.028876+00:00","id":2064307,"links":{},"metadata":{"_buckets":{"deposit":"787fa94e-4ac7-4902-8c61-6354f552afe7"},"_deposit":{"id":"2064307","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"2064307"},"status":"published"},"_oai":{"id":"oai:teikyo-u.repo.nii.ac.jp:02064307","sets":["1726879085919:1741828256493"]},"author_link":[],"item_1551264308487":{"attribute_name":"Title","attribute_value_mlt":[{"subitem_title":"The Design and Characterization of Dielectric Microcalorimeters for X-ray Photon Detection","subitem_title_language":"en"}]},"item_1551264340087":{"attribute_name":"Creator","attribute_type":"creator","attribute_value_mlt":[{"familyNames":[{"familyName":"kikuchi","familyNameLang":"en"},{"familyName":"菊池","familyNameLang":"ja"}],"givenNames":[{"givenName":"tadashi","givenNameLang":"en"},{"givenName":"正","givenNameLang":"ja"}]},{"familyNames":[{"familyName":"hoshino","familyNameLang":"en"},{"familyName":"星野","familyNameLang":"ja"}],"givenNames":[{"givenName":"manabu","givenNameLang":"en"},{"givenName":"学","givenNameLang":"ja"}]},{"familyNames":[{"familyName":"Nakayama"}],"givenNames":[{"givenName":"T."}]},{"familyNames":[{"familyName":"Yamasaki"}],"givenNames":[{"givenName":"N. Y."}]},{"familyNames":[{"familyName":"maehata","familyNameLang":"en"},{"familyName":"前畑","familyNameLang":"ja"}],"givenNames":[{"givenName":"keisuke","givenNameLang":"en"},{"givenName":"京介","givenNameLang":"ja"}]},{"familyNames":[{"familyName":"Mitsuda"}],"givenNames":[{"givenName":"K."}]}]},"item_1551264447183":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_16ec"}]},"item_1551264846237":{"attribute_name":"Description","attribute_value_mlt":[{"subitem_description":"The dielectric micro calorimeter (DMC) is a novel radiation detector utilizing a GHz resonator with dielectric thermometer (Sekiya et al. in J Low Temp Phys 167:435, 2012). The advantage of using a DMC is that the detection mechanism is based on a phonon mediation without Johnson noise and quasi-particle decay process. A large format array of DMCs can be easily multiplexed by a resonator circuit in the readout at GHz band width. We describe the design of a DMC as an X-ray photon counter. It is optimized to detect photon at 5.9 keV energy. We consider O-doped SrTiO (STO18) and Nb-doped KTaNbO (KTN) as a candidate of dielectric thermometer. Dielectric materials which have sensitivity (= d) are also ideal for our application. We check that both STO18 and KTN have at 100 mK. If we assume a DMC resonator operating at 100 mK, we need a Q value of a resonator to be 2000 for X-ray detection.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_1551264974654":{"attribute_name":"Date","attribute_value_mlt":[{"subitem_date_issued_datetime":"2016-7","subitem_date_issued_type":"Issued"}]},"item_1551265002099":{"attribute_name":"Language","attribute_value_mlt":[{"subitem_language":"en"}]},"item_1551265032053":{"attribute_name":"item_1551265032053","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_1551265227803":{"attribute_name":"Relation","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"WOS:000378689800040","subitem_relation_type_select":"WOS"}},{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"84961794338","subitem_relation_type_select":"SCOPUS"}}]},"item_1551265409089":{"attribute_name":"Source Identifier","attribute_value_mlt":[{"subitem_source_identifier":"0022-2291","subitem_source_identifier_type":"ISSN"}]},"item_1551265438256":{"attribute_name":"Source Title","attribute_value_mlt":[{"subitem_source_title":"JOURNAL OF LOW TEMPERATURE PHYSICS"}]},"item_1551265463411":{"attribute_name":"巻","attribute_value_mlt":[{"subitem_volume":"184"}]},"item_1551265520160":{"attribute_name":"号","attribute_value_mlt":[{"subitem_issue":"1-2"}]},"item_1551265553273":{"attribute_name":"ページ数","attribute_value_mlt":[{"subitem_number_of_pages":"7"}]},"item_1551265569218":{"attribute_name":"開始ページ","attribute_value_mlt":[{"subitem_start_page":"250"},{"subitem_start_page":"256"}]},"item_title":"The Design and Characterization of Dielectric Microcalorimeters for X-ray Photon Detection","item_type_id":"12","owner":"1","path":["1741828256493"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2025-04-02"},"publish_date":"2025-04-02","publish_status":"0","recid":"2064307","relation_version_is_last":true,"system_identifier_doi":{"attribute_name":"Persistent Identifier(DOI)","attribute_value_mlt":[{"subitem_systemidt_identifier":"https://doi.org/10.1007/s10909-016-1587-8","subitem_systemidt_identifier_type":"DOI"}]},"title":["The Design and Characterization of Dielectric Microcalorimeters for X-ray Photon Detection"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2025-06-01T01:27:49.280649+00:00"}